Pressure sensor installation

The pressure sensor is installed in the valve block at the site designated by the valve manufacturer.
The mounting location must ensure spraying pressure measurement in the valve section. Usually,
the pressure sensor is mounted at the end or at the beginning of a electric valves series. In order
to ensure proper pressure reading, it is recommended to install an analogue pressure gauge to
enable comparison of readings.


Connect the pressure sensor to the PRESSURE cable in the wiring harness.

Figure 5.235 Instructions for connecting the pressure sensor. It is important to screw the sensor into the valve
block group first and then connect the PRESSURE cable plug. 1 – Pressure sensor; 2 – Valve group block;

The pressure sensor is extremely vulnerable to negative temperatures, especially when there are water residues inside. It is recommended to remove the sensor from the valve section for the winter.